Welcome to 3D plus.com
Home >> Products >> Quality levels
 
3D PLUS products


 

3 quality levels available : Commercial, Industrial or Space. The table below describes these 3 quality levels according to the stacking technology (TSOP stacking or Flex Stacking).
In space terminology, Engineering Models (EM) correspond to the Industrial level and Flight Models (FM) correspond to the Space level.

>> Check Notes


Flow 1
Flow 2
/Steps
Commercial
Industrial
Space
TSOP stacking
Flex stacking
       
3D PLUS applicable documentation      
   

Process Identification Document (PID)

   

Module procurement specification

   
   

Module test specification

Components lots traceability
Components Lot Acceptance Test (LAT)
Manufacturing traceability for each module lot
 
Flex assembly according to PID
 
Electrical test at +25°C - Go/NoGo
 
Burn-in flex 168hrs +125°C followed by an electrical test at +25°C – Go/NoGo    
 
Flex Precap visual inspection before stacking    
Module Manufacturing according to the PID
Electrical test at +25°C - Go/NoGo
Module screening      
    Stab. Bake 72hrs +125°C  
    Thermal cycles (x10)–55°C/+125°C  
    Electrical test at +25°C pre burn-in with R&R    
    Burn-in 168hrs +125°C  
    Electrical test at Tmin, +25°C, Tmax,
(Note 8)
 

(Go/NoGo)

(R&R)
    Parameters drift calculation at +25°C    
    P.D.A. calculation    
    Final external visual inspection
    Dimensions measurements
(3 modules)
Modules serialisation  
Module Lot Acceptance Test - (Note 7)      
    Life test 1000hrs +125°C    
    Electrical test at Tmin, +25°C, Tmax, Post life test with R&R – (Note 8)    
    Parameters drift calculation à +25°C    
    Final external visual inspection    
    Final DPA (1 module)    
Customer source inspection    
Documentation delivered
 


^ Top